INSTALLATION
WIRING INSTRUCTIONS
The ENTRACOMP
®
26SA is provided with a connector and 7 wire
leads (See Figure 1). Using appropriate wire nuts or crimp on
connectors, wire the unit as per the table below. Be sure unused
wires are insulated to avoid shorting. In addition to the wiring below,
AN EARTH GROUND IS REQUIRED. It must be connected to the
green screw on the mounting bracket .
WIRE COLOR DESCRIPTION
1 WHITE
10-24 VAC OR
10-24 VDC
2 WHITE
3 YELLOW
NORMALLY OPEN
*
4 N/A NOT USED
5 GREEN COMMON
6 N/A NOT USED
7 RED 8 VDC FOR SECURELAY™
8 N/A NOT USED
9 ORANGE REMOTE OPEN
10 BROWN REMOTE OPEN
* Can be reprogrammed as Normally Closed, See page 10.
TABLE 1
Secura Key • 11